KalyxX RedLine
Treat the water once, at the main line, and reduce scale across every pipe, valve, tap and heating coil downstream.
- TGP® patented
- 76% reduction
- No external energy
- Stainless steel 1.4301
Main-line system using patented TGP® Turbulent Galvanic Polarisation, with a manufacturer-confirmed 76% limescale-formation reduction across pipework, valves, taps and heating coils.
Request price
RedLine is sized to your main-line connection and peak flow. Send your pipe size and water details for a quotation.
- Confirmed limescale-formation reduction
- 76%Confirmed limescale-formation reduction
- Patented Turbulent Galvanic Polarisation
- TGP®Patented Turbulent Galvanic Polarisation
- No chemicals, no external energy
- 0 kWhNo chemicals, no external energy
- Maximum flow, largest model
- 7 m³/hMaximum flow, largest model


Technology
TGP® Turbulent Galvanic Polarisation
Water is forced into a turbulent path across a structured electrode arrangement inside the stainless steel body. The galvanic effect changes how dissolved calcium and magnesium behave, so hardness minerals are less likely to bond to pipe walls and heating surfaces — with no chemicals and no external energy.
- Reduces limescale formation on pipework, valves, taps, shower heads and the water-heating coils of appliances.
- Operates without chemicals and without any external energy supply.
- Suitable for cold drinking water; the manufacturer references an NRL assessment for permanent contact with drinking water.
- Parts use materials suitable for drinking-water contact.
- Hydraulic properties tested for pressure drop, pressure resistance and strength (TSU, referenced by the manufacturer).
- Stainless steel 1.4301 body. The manufacturer's overview states a 2-year warranty and expected service of at least 10 years.
Results depend on water conditions, hardness, flow rate, installation quality and the product selected.
Where it helps
Pipework and valves
Reduces limescale formation along the distribution pipework and valves after the inlet.
Taps and shower heads
Helps keep outlets and nozzles clearer of hard scale deposits.
Water-heating coils
Reduces scale formation on the heating coils of connected appliances.
Homes and larger systems
Suitable residential and larger water systems, sized by flow rate and pipe diameter.
Sizing
Choose your model
Five sizes are available. Select a size to see its full technical data — every figure is also listed in the table below.
| Model | Connection | Diameter | Length | Weight | Max pressure | Max flow | Pressure drop | Min flow |
|---|---|---|---|---|---|---|---|---|
| RedLine 1/2" | G 1/2" female | 50 mm | 245 mm | 910 g | 10 bar / 1 MPa | 1 m³/h | 0.4416 mbar / 44.16 Pa | 5 L/min |
| RedLine 3/4" | G 3/4" female | 50 mm | 245 mm | 890 g | 10 bar / 1 MPa | 3.2 m³/h | 4.38 mbar / 437.78 Pa | 5 L/min |
| RedLine 1" | G 1" female | 50 mm | 251 mm | 930 g | 10 bar / 1 MPa | 4 m³/h | 6.92 mbar / 692.03 Pa | 5 L/min |
| RedLine 5/4" | G 5/4" female | 50 mm | 480 mm | 2400 g | 10 bar / 1 MPa | 5 m³/h | 13.84 mbar / 1,384.06 Pa | 5 L/min |
| RedLine 6/4" | G 6/4" female | 50 mm | 480 mm | 2500 g | 10 bar / 1 MPa | 7 m³/h | 13.84 mbar / 1,384.06 Pa | 5 L/min |
General specifications
| Parameter | Detail |
|---|---|
| Technology | TGP® Turbulent Galvanic Polarisation (patented) |
| Installation point | In-line on the main cold water inlet |
| Body material | Stainless steel 1.4301 |
| Connection | Female NPT/G × female NPT/G |
| Pipe compatibility | Copper, CPVC, PVC, PEX |
| Maximum flow rate | Up to 7 m³/h depending on model |
| Operating inlet temperature | 0–85 °C |
| Optimal inlet temperature | 0–60 °C for maximum efficiency |
| Energy / chemicals | None required |
| Warranty (manufacturer) | 2 years; expected service at least 10 years |
Is your water suitable?
- pH6.5 – 8.5
- Iron< 0.5 mg/L
- Hardness< 25 °dH (4.464 mmol/L)
- Electrical conductivity< 150 mS/m
- TDS< 950 ppm
- Salinity< 2000 mg/L
Installation warning: do not place RedLine close to devices producing strong electromagnetic fields, especially motors or pumps. Normal household electrical conductors and small appliances are not described as strong enough to affect function.
High chlorine content may reduce IPS electrode lifespan by about 50%. If your water differs from the recommended properties, ask us for an individual assessment.
Installation

Main-line installation
Fitted in-line on the main cold water inlet by a qualified plumber, with correct orientation and isolation valves.
Pipe compatibility
Copper, CPVC, PVC and PEX. Connection is female NPT/G × female NPT/G.
Limitations
RedLine reduces limescale formation. It does not soften water, does not remove dissolved minerals and is not a purifier.
Manufacturer-listed approvals and reports
- IAPMO
- TÜV
- NRL
- TSU
- CNAS
The official Swiss Aqua Technologies page lists IAPMO, TÜV, NRL, TSU and CNAS-related approvals and reports for KalyxX RedLine. These are referenced here exactly as the manufacturer lists them. EIMEX does not claim any certification beyond those documents, and copies can be requested with your quotation.
Questions about RedLine
Protecting a single appliance?
The compact KalyxX 100 Mini may be the better fit.